Category: True Online UPS Single phase
Model Name: Hercules RT G2 6kVA/6kW
Model Number: HE-RT6K-G2
     Download Brochure
Check Alarm Code
 Features
  - THE SUPERB PERFORMANCE UPS
  - N+X Parallel Redundancy
  - DSP Control
  - 1.0 Output Power Factor
  - Wide Input Range 110-275VAC
  - Maintenace Bypass Switch
  - Configurable Battery Quantity 16 to 20 pcs per string
  - Frequency Converter Mode
  - Input THDI <3%
  - Output THDv <1% @ linear
  - Battery capacity/Remaining Time calculation
  - Event Log via LCD panel
  - High Efficiency Inverter Mode @95%
  - Varity of Communication Ports: RS232,USB,EPO,DryIn/DryOut
  - Optional SNMP & Relay Cards
  - Over Voltage Cut-Off device (OVCD) for tough environment
คลิกดูรายละเอียด OVCD
  - LED & LCD Display
  - Charger current is adjustable, 1A to 12A through LCD penel
  - Short Circuit Clearance with current limit
  - High Efficiency Mode (EPO)
  - Free Power Management Software
  - CE Declaration of Conformity
 

Product Descriptions

Hercules-RT-G2 Series UPS is a features rich UPS that make use of the unique True Online Double Conversion circuitry to detect the electricity current and voltage output of utility power supply. The current is input via high frequency PWM to maintain uniform wave form and phase in line with the voltage, so as to attain high input power factor over to 0.995 and avoid generating comparatively significant harmonic interference on the power network. With the use of the outstanding IGBT as the power convertion component, so as to get the full performace of output capacity at PF 1.0, Higher working efficiency of the inverter also improves the overall efficiency of UPS upto 95% and higher inversion frequency reduces the noise of the inverter as well.
*คลิกดูเทคนิค True Online Double Conversion

TypeItemsSpecification
CapacityCapacity6000VA/6000W
InputVoltage Range110 (+/-3%) ~ 275 (+/-3%) VAC (176-275VAC@100 load)
 Frequency Range50 +/- 10% Hz
 PhaseSingle Phase with Ground
 Current THDI@100%Load<3%
 Power Factor@100%Load>= 0.995
 Generator InputSupport (1.5 x UPS Rating Power)
OutputVoltage Range220 +/- 1% VAC
 Frequency Range50 +/- 0.1% Hz
 Crest Factor3:1
 Harmonic Distortion< 1% THD (Linear Load)
 Output Wave formPure Sine Wave
 OutletTerminal Block
 Overload Capacity10 min @ 105%-125%; 30s @ 125%-125%;500 msec@>150%
 Redundancy (Option)N+X Parallel Redundancy (Max 3)
EfficiencyAC mode>95%
 Battery Mode>95%
 ECO>98%
BatteryNumber of Battery16/17/18/19/20 pcs. per string adjustable
 Battery type12V/(7/9)Ahr (Sealed Lead-Acid Maintenance Free with suspended electrolyte) or on requested
 Backup time>15 min (Depend on computer load)
 Recharge Time (to 90%)3 hrs.
Transfer TimeTransfer Time0 ms.
IndicatorLCD & LED versionLoad, Battery, Input, Output, Operation Mode Information
Audible AlarmBattery ModeSounding every 4 seconds
 Low BatterySounding every second
 OverloadSounding twice every second
 FaultContinuously Sounding
DimensionRT Case (WxHxD)mmUPS (RT 2U) 438x86x573,EBM (RT 3U) 438x129x593
WeightTower Case (kgs)UPS (RT 2U): 13kg, EBM(RT 3U) 45.4Kg
EnvironmentOperation Environment0-40 C
 Relative Humidity0-95% (Non-Condensing)
 Noise Level<45dB @ 1 Meter
InterfaceRS-232 & USBS/W supports Windows Family, Linux, Sun Solaris, IBM AIX, Compaq True64, SGI IRIX, FreeBSD, HP-UX and MAC
 External Slot (Option)Internal Type of SNMP / AS400 Relay Card / RS485
International Standard CESafety (IEC62040-1-1), EMC: IEC/EN 62040-2, IEC 61000-4-2(ESD):level 3, IEC 61000-4-3 (Radiated field): level 3, IEC 61000-4-4(EFT):level 4, IEC61000-4-5 (Fast transients): level 4, IEC 61999-4-6 (Electromagnetic field): level 3, IEC 61000-4-8 (Conducted magnetic field):level 4, Performance: IEC/EN 62040-3