Type | Items | Specification |
Capacity | Capacity | 750VA/500W |
Input | Voltage Range | 220 + 25% -23%VAC |
| Frequency Range | 50 +/- 10% Hz |
| Phase | Single Phase with Ground |
| Generator Input | Support |
Output | Voltage Range | 220 +/- 10% VAC |
| Voltage Range (Batt.Mode) | 220 +/- 10% RMS for entire battery voltage range |
| Frequency Range | 50 +/- 0.1% Hz |
| Output Wave form | Pure Sine Wave |
| Outlet | NEMA x 5 |
Overload Rating | Line Mode | 110% shutdown after 3 minute; 130% shutdown after 10 cycles. |
| Battery Mode | 110% shutdown after 30 sec.;120% shutdown after 5 cycles. |
Battery | Battery type | 12V/9A (Sealed Lead-Acid Maintenance Free with suspended electrolyte) or on requested |
| Number of Battery | 1 pcs. or on requested |
| 50% load backup time | 8 minutes |
| 1 PC backup time (typical) | 26 minutes 30 sec |
| Battery hot swap | YES |
| Battery Protection | Battery Overcharges/Battery deep discharge/Auto self test/Fan failure protection |
| Recharge Time | <8 hrs to 90% |
Transfer Time | Transfer Time | 2 ms. |
Indicator | LED display | UPS status, Load Level, Battery Level, Fault |
Audible Alarm | Battery Mode | Sounding every 10 seconds |
| Low Battery | Sounding every second |
| UPS Fault | Continuously Sounding |
| Overload | Sounding every 0.5 second |
| Battery Replacement | Sounding every 3 second |
| Over charge | Sounding every 1.5 seconds |
| Over termperature | Sounding every 2.5 seconds |
| Charger fail | Sounding every 3 seconds |
Dimension | Tower Case (LxWxH)mm | 323x96x234.6 mm |
Weight | Tower Case (kgs) | 6 |
Environment | Operation Environment | 0-40 C |
| Relative Humidity | 0-90% (Non-Condensing) |
| Noise Level | <40dB @ 1 Meter |
Interface | Smart RS-232 / USB | S/W supports Windows Family, Linux, Sun Solaris, IBM AIX, Compaq True64, SGI IRIX, FreeBSD, HP-UX and MAC |
| External Slot (Option) | External Type of SNMP |
International Standard | CE | Low Voltage Directive(Safety): EN62040-1-1,
EMC Directive: EN62040-2 C2,EN62040-2,EN61000-3-2 |